{"product_id":"brewery-chiller-brewchill-pro-7500-7500-btus-canada-only","title":"Brewery Chiller - BrewChill Pro 7500 - 7500 BTUs","description":"\u003cp\u003e\u003cspan\u003e \u003cimg alt=\"icon-pdf.png\" class=\"__mce_add_custom__\" height=\"32\" src=\"https:\/\/cdn11.bigcommerce.com\/s-2pml8e\/content\/specification\/Specification_pdf.svg\" title=\"icon-pdf.png\" width=\"32\"\u003e \u003ca href=\"https:\/\/www.beveragecraft.com\/content\/specification\/glycol-chillers\/CP-7500-1.pdf\" target=\"_blank\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e \u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003cimg alt=\"icon-pdf.png\" class=\"__mce_add_custom__\" height=\"32\" src=\"https:\/\/cdn11.bigcommerce.com\/s-2pml8e\/content\/specification\/Specification_pdf.svg\" title=\"icon-pdf.png\" width=\"32\"\u003e \u003ca href=\"https:\/\/www.beveragecraft.com\/content\/specification\/glycol-chillers\/BC-7500-2.pdf\" target=\"_blank\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOnce a Canadian brewery moves past pilot scale, cooling needs change: bigger tanks, longer brew days, and less room for a glycol chiller that can't keep up. The \u003cstrong\u003eBrewChill Pro 7500-2\u003c\/strong\u003e ships with two 80 gallon per hour vane pumps installed from the factory, both running off the same thermostat, so you get one setpoint across multiple tanks rather than independent zones. If you need two tanks at different temperatures at the same time, look for a model built with two separate thermostats instead.\u003cbr\u003eAt 7,500 BTU per hour on 208 to 230 volt power, it handles wort chilling, fermentation and bright tank control in setups up to 1,500 liters, backed by an 18 gallon reservoir. Breweries usually move up to this model once a smaller chiller starts falling behind, and the same cooling capacity works well in wineries or cideries managing a full room of tanks through a busy season.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo pumps, one setpoint:\u003c\/strong\u003e Two built-in 80 gal\/hr \u003ca href=\"https:\/\/www.beveragecraft.com\/pumps-and-motors\/\" target=\"_blank\"\u003evane pumps\u003c\/a\u003e on separate 1\/3 HP motors. Both share the same thermostat, so it's one setpoint, not independent zones.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7,500 BTU\/h capacity:\u003c\/strong\u003e Rated for \u003ca href=\"https:\/\/www.beveragecraft.com\/stainless-steel-tanks\/\" target=\"_blank\"\u003efermentation tanks up to 1,500 liters\u003c\/a\u003e, built for medium-batch Canadian breweries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient at scale:\u003c\/strong\u003e A 1 HP \u003ca href=\"https:\/\/www.beveragecraft.com\/compressors-beverage-refrigeration-parts\/\" target=\"_blank\"\u003ecompressor\u003c\/a\u003e on R290 refrigerant, strong cooling without a big jump in power costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade reliability:\u003c\/strong\u003e Suited to microbreweries, brewpubs and advanced homebrewers who need consistent performance under demanding use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuick to install:\u003c\/strong\u003e 3\/4\" NPT fittings, 6-ft power cord, NEMA 6-20P plug for fast setup in new or existing Canadian systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e450-ft line reach:\u003c\/strong\u003e Flexible placement across larger brewing facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for long runs:\u003c\/strong\u003e Designed to hold steady cooling through extended, high-demand brewing sessions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003e\u003cspan\u003eParts Included:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e1 × BrewChill Pro 7500 (80 GPH pump, 1\/3 HP motor)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e1 × External digital thermostat\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e4 × Solenoid valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-bordered specification-tab\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch6\u003eBrewChill Pro 7500 - Canada\u003c\/h6\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODEL\u003c\/td\u003e\n\u003ctd\u003eBC-7500-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXIMUM DISTANCE\u003c\/td\u003e\n\u003ctd\u003eUp to 450 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003e7500 BTU\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL TANK CAPACITY\u003c\/td\u003e\n\u003ctd\u003e18 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMPRESSOR POWER\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUNNING\u003c\/td\u003e\n\u003ctd\u003eWith 1 pump - 10.0 AMP\u003cbr\u003eWith 2 pimps - 12.8 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLUG TYPE (NEMA #)\u003c\/td\u003e\n\u003ctd\u003e6-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOLTAGE\u003c\/td\u003e\n\u003ctd\u003e208\/230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREQUENCY\u003c\/td\u003e\n\u003ctd\u003e60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP TYPE\u003c\/td\u003e\n\u003ctd\u003eVane with 1\/3hp motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP\u003c\/td\u003e\n\u003ctd\u003e80 GPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF PRE-INSTALLED PUMPS\u003c\/td\u003e\n\u003ctd\u003e 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF ADDITIONAL PUMPS\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT\u003c\/td\u003e\n\u003ctd\u003e R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT CHARGE, G (OZ)\u003c\/td\u003e\n\u003ctd\u003e 150 (5.29)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e WEIGHT GROSS\/NET\u003c\/td\u003e\n\u003ctd\u003e 154 \/ 147 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e POWER CORD LENGTH\u003c\/td\u003e\n\u003ctd\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e INLET\/OUTLET BARB, IN\u003c\/td\u003e\n\u003ctd\u003e red tube 3\/4” NPT \/ blue tube 3\/4” NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e OPERATING AMBIENT TEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e 60-90 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CLEARANCE AT LEAST\u003c\/td\u003e\n\u003ctd\u003e 12\" around the entire unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL MIXTURE, VOL%\u003c\/td\u003e\n\u003ctd\u003e40 % glycol and 60% water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNote: Installation of this item must be handled by a qualified installer in order to qualify for product return and\/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services, and possesses a business license, contractor's license, and\/or resale permit. Common examples of a \"qualified installer\" include Electrician; General Contractor; Heating and Air Conditioning Specialist.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf you want to confirm 7,500 BTU matches your tank count, our \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-sizing-calculator\/\" target=\"_blank\"\u003ebrewery chiller sizing calculator\u003c\/a\u003e walks through the numbers directly. Larger production setups running at full capacity tend to move up to the \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-brewchill-pro-13000-13000-btus-canada-only\/\" target=\"_blank\"\u003eBrewChill Pro 13000-2\u003c\/a\u003e for its extended 750 foot glycol lines. If you would like help mapping out your glycol lines, \u003ca href=\"mailto:sales@beveragecraft.com\" target=\"_blank\"\u003econtact us\u003c\/a\u003e and our team will walk through the layout with you.\u003c\/p\u003e","brand":"BeverageCraft","offers":[{"title":"BrewChill Pro 7500-2","offer_id":42776753569838,"sku":"BC-7500-2-ASM","price":4206.49,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1285\/0577\/files\/CP-7500-2__58652__02015.1787202896.webp?v=1791683766","url":"https:\/\/torontobrewing.ca\/products\/brewery-chiller-brewchill-pro-7500-7500-btus-canada-only","provider":"Toronto Brewing","version":"1.0","type":"link"}