Skip to content

Advantage Engineering - Water and Glycol Chillers

Advantage - Chillers and Accessories, Temperature Control Units, Evaporative Cooling Towers, Pump Tank Stations

Advantage BC Series Indoor Glycol Chillers Toronto Brewing is an exclusive Canadian partner and distributor for Advantage Engineering Water Chillers and Glycol Chillers. Together, our knowledgeable application, product and service specialists are always available to discuss your needs and help you find the best solution for your specific requirements.

Indoor Glycol Chillers

Indoor Advantage glycol chillers are ideal for breweries and production facilities with available indoor mechanical space.

Model Capacity Compressor Flow
BC-1A 5,288 BTU/hr 1 HP 2.4 GPM
BC-1.5A 9,028 BTU/hr 1.5 HP 3.6 GPM
BG-2A 14,192 BTU/hr 2 HP 4.8 GPM
BGD-3A 17,292 BTU/hr 3 HP 7.2 GPM
BGD-5A 30,512 BTU/hr 5 HP 12 GPM
BGD-7.5A 45,512 BTU/hr 7.5 HP 18 GPM
BGD-10A 62,412 BTU/hr 10 HP 24 GPM
BGD-15AF 95,368 BTU/hr 15 HP 36 GPM
BG-20AF 117,274 BTU/hr 20 HP 48 GPM
BG-25A 149,456 BTU/hr 25 HP 60 GPM
BG-30A 197,456 BTU/hr 30 HP 72 GPM

Outdoor Glycol Chillers

Outdoor Advantage glycol chillers are available for facilities that need to preserve indoor floor space or require larger central cooling capacity.

Model Capacity Compressor Flow
BG-2A-N4 14,192 BTU/hr 2 HP 7.2 GPM
BG-3A-N4 17,992 BTU/hr 3 HP 10 GPM
BGD-5A-N4 30,512 BTU/hr 5 HP 12 GPM
BGD-7.5A-N4 45,512 BTU/hr 7.5 HP 18 GPM
BGD-10A-N4 62,412 BTU/hr 10 HP 24 GPM
OACS-15S-MG-1P-BC 95,368 BTU/hr 15 HP 36 GPM
OACS-20S-MG-1P-BC 117,274 BTU/hr 20 HP 48 GPM
OACS-30-MG-1P-BC 197,456 BTU/hr 30 HP 72 GPM
OACS-50S-MG-1P-BC 323,000 BTU/hr 2 × 25 HP 120 GPM
OACS-100D-MZC-2P-BC 654,000 BTU/hr 2 × 50 HP 240 GPM
OACS-210D-MZC-2P-BC 1,224,000 BTU/hr 2 × 110 HP 490 GPM

Temperature Controllers:

Sentra Series Water Temperature Control Units

Advantage Sentra SK Series Water Temperature Control Units
Cooling water supply for the Sentra is required from an external source.
  • 30° to 300°F Process Temperatures
  • 6 to 34 kW Heaters
  • 1/2 to 7.5 HP Centrifugal Pumps (20 – 100 GPM)
  • 1/2 inch and 3/4 inch AVT™ Modulating Cooling Valves (LE & HE models)
  • 3/8 inch – 1 inch Solenoid Cooling Valves (VE & 300°F models)

Regal Series Oil Temperature Control Units

Advantage Regal RK Series Oil Temperature Control Units
  • 100° to 500°F Process Temperatures
  • 12 to 48 kW Heaters
  • 1 to 7.5 HP Centrifugal Pumps (20 – 100 GPM flow rates)
  • 3.6 square foot Heat Exchanger (included on HC models)
  • Choice of Microprocessor Control Instruments

Central Water Chillers:

Advantage Central Chillers

Central Water Chillers service multiple use points throughout the plant. Central chillers are stationary, and require a circulating system to distribute water to the process. Central chillers are offered in capacities from 20 to 500 tons.

ADVANTAGE central chillers are offered as MODULES and PACKAGES. A module is a stand-alone chiller unit that requires a pump tank station to distribute the chilled water. A package is a self-contained unit with the chiller and pump tank station on a single platform.

Water-Cooled WPT Modules with 5 – 180 tons of Cooling Capacity

  • Provide a coolant temperature range between 20˚F and 80˚F when using R410A refrigerant
  • Equipped with Hermetic Scroll Compressors or Tandem Scroll Compressors

Air-Cooled APT Modules

Advantage APT-RC Series Air Cooled Central Chillers
  • 5 – 180 ton Models
  • 20˚ – 80˚F Fluid Temperature Range
  • Available in Single, Dual, and Triple Refrigerant Models
  • Uses a Non-Ozone Depleting Refrigerant

OACS Outdoor Air-Cooled Central Chillers

Advantage OACS Series Central Water Chillers

Advantage OACS systems are designed to be installed outside using no valuable indoor floor space and are a complete package including water reservoir and pumping system. The system is fully factory tested before shipment and requires minimal installation.

OACS systems are available with 1 or 2 independent refrigeration zones for energy efficient capacity staging and to provide partial or full redundancy.

  • Complete Central Chiller System with Integrated Reservoir and Pump all mounted on a single frame
  • Outdoor Installed Air-Cooled Design
  • 5 – 210 ton Models
  • 20˚ – 80˚F fluid temperature range for models using R410A refrigerant
  • 20˚ – 65˚F fluid temperature range for models using R407C refrigerant

Titan Central Chillers

Advantage Titan Central Chillers configured with reservoir and pumps housed in a single frame – making it a complete self-contained package which reduces installation costs compared to other systems.

The Titan systems can be air-cooled or water-cooled. Air-cooled models require an outdoor remote condenser. Water-cooled models require an external water supply source such as cooling tower, city or well water to reject the heat removed from the refrigeration circuit.

Both air-cooled and water-cooled Titan Chillers can be configured for future expansion to meet your growing cooling needs with the addition of APT or WPT chiller modules.

  • 20 – 180 tons of Cooling Capacity
  • 20˚ – 80˚F fluid temperature range when using R410A refrigerant
  • Complete self-contained package
  • Air-Cooled or Water-Cooled models available

Portable Water Chillers:

Advantage Portable Chillers

Advantage Portable Chillers supply temperatures between 20° to 70°F, are self contained units, and use a refrigerant system to chill water. The chilled water is stored in a reservoir and supplied to the process using a circulating pump.

Custom designed microprocessor instrumentation control the unit’s operation. Portable chillers can service single or multiple process cooling points, and are designed to be moved between process applications as needed.

Portable Chillers for EDM Machine Cooling

Advantage’s purpose built Air-Cooled Portable Chillers for EDM Machine Cooling Applications provide these features:

  • Indoor Units
  • Air-Cooled Condenser
  • 20˚ – 80˚F Fluid Temperature Range
  • Non-Ozone Depleting Refrigerant

Maximum Series Portable Chillers

Advantage’s Maximum Series Portable Chillers are refrigeration units coupled with an integral fluid circulation system. They range in cooling capacity from 1/4 to 40 tons.

  • Indoor Units
  • Easy Installation, requiring only a source of electrical power, coolant fluid, and a process load to be temperature controlled
  • Available in Air-Cooled or Water-Cooled models
  • Can be configured with a remote, air-cooled condenser to decrease heat within your facility
  • 1/4 – 40 ton Cooling Capacity

Evaporative Cooling Towers:

Advantage 405 ton Power Tower Cooling Tower

Through extensive development and testing, the Power Tower cooling tower cells are space efficient, highly versatile and have a lower first cost and operating cost when compared to other cooling methods.

Advantage’s Power Tower is simple to operate with easy to understand controls and utilizes energy-efficient evaporative cooling to provide cooled water for a variety of industrial applications and equipment.

The falling water and counter airflow causes a portion of the warm process water to evaporate. The small amount of water evaporating cools the remaining water. Under design conditions about 1% of the water flow rate evaporates to achieve the cooling affect desired.

  • Built for the Industrial environment
  • Long lasting: All wetted surfaces are made of fiberglass, stainless steel, PVC or other non-rusting material
  • Reduced Maintenance: Closed loop system with only one moving part requiring periodic lubrication
  • Easy to Install with clearly labeled process connection and power requirements

Power Tower Series Cooling Towers

Advantage’s Power Tower Series Evaporative Cooling Towers are made of durable UV protected fiberglass with a counter air flow design.

  • Space and Energy Efficient
  • Capacities from 45 to 540 tons
  • Maintains full capacity and temperature control stability over a wide range of wind, air temperature, and humidity extremes
  • Nominal rating condition is cooling 3 gallons per minute per ton of capacity from 95°F to 85°F at 78°F wet bulb

Pump Tank Stations:

Advantage Pump Tank Stations

Advantage Pump Tank Stations are an integral part of evaporative cooling tower, fluid cooler and chilled water cooling systems. Pump Tank Stations provide a stable reservoir of cooling fluid that minimizes the affects of cooling load changes.

Pump Tank Stations are generally installed indoors and consist of a vented reservoir along with fluid pumps and controls that are selected to meet the specific needs of your system.

  • Available in 1-Pump and 2-Pump System Configurations
  • A 3/8″ dense foam insulation is applied to the outside of the reservoir on chilled water systems to prevent sweating and heat gain
  • Can be equipped with controls as basic as manual push button motor starters and thermostats

TTK Tough Tank

Advantage TTK Tough Tank Pump Tank Station

Advantage Tough Tank is a one-piece, cylindrical, seamless, rotationally molded linear low density polyethylene tank that will not rust or corrode.

The Tough Tank includes a drain valve, mechanical water make-up system and overflow port creating a fully engineered package ready to run.

  • 400, 800, 1,500 & 3,000 gallon capacities
  • Hinged tank lid for easy access
  • On 2-pump systems, an internal baffle provides hot/cold water service
  • A sight tube provides easy level verification
  • 10 year tank failure warranty

PTS-CPTS Reservoir

Advantage PTS-CPTS Reservoir Pump Tank Stations are constructed from epoxy coated mild steel or stainless steel welded sheet.

The PTS-CPTS includes a drain valve, mechanical water make-up system and overflow port creating a fully engineered package ready to run.

  • 275 – 3,000 gallon capacities
  • Internal baffle provides hot/cold water service on 2-pump systems
  • 1 year warranty